SBE 19plus V2
SEACAT Profiler
Conductivity, Temperature, and Pressure Recorder
with RS-232 Interface
Note: NEW ADDRESS
As of January 2010
User’s Manual
Sea-Bird Electronics, Inc.
13431 NE 20
th
Street
Bellevue, Washington 98005 USA Manual Version #006, 04/21/11
Telephone: +1 425-643-9866 Firmware Version 2.3 and later
Fax: +1 425-643-9954 SeatermV2 Version 1.1e and later
[email protected] Seasave V7 Version 7.21d and later
www.seabird.com SBE Data Processing Version 7.21d and later
Vue de la page 0
1 2 3 4 5 6 ... 123 124

Résumé du contenu

Page 1 - SEACAT Profiler

SBE 19plus V2 SEACAT Profiler Conductivity, Temperature, and Pressure Recorder with RS-232 Interface Note: NEW ADDRESS As of Ja

Page 2 - Limited Liability Statement

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 10 • SBE 55 ECO Water Sampler - The SBE 55 has built-in capabilities simi

Page 3 - Table of Contents

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 100 Replacing Anti-Foulant Devices (SBE 16plus, SBE 19plus) The S

Page 4

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 101 Sensor Calibration Sea-Bird sensors are calibrated by subjecti

Page 5 - Section 1: Introduction

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 102 Pressure Sensor The SBE 19plus V2 includes a standard strain-g

Page 6 - Unpacking SBE 19plus V2

Manual revision 006 Section 6: Troubleshooting SBE 19plus V2 103 Section 6: Troubleshooting This section reviews common problems in operating the S

Page 7 - System Description

Manual revision 006 Section 6: Troubleshooting SBE 19plus V2 104 Problem 3: Nonsense or Unreasonable Data The symptom of this problem is a data fil

Page 8

Manual revision 006 Glossary SBE 19plus V2 105 Glossary Batteries – Nine alkaline D-cells (Duracell MN1300, LR20) standard. Available with optional

Page 9

Manual revision 006 Glossary SBE 19plus V2 106 Seaterm232 – Win 2000/XP terminal program used with Sea-Bird instruments that communicate via an RS-2

Page 10

Manual revision 006 Appendix I: Functional Description and Circuitry SBE 19plus V2 107 Appendix I: Functional Description and Circuitry Sensors T

Page 11 - Specifications

Manual revision 006 Appendix I: Functional Description and Circuitry SBE 19plus V2 108 Battery Wiring SBE 19plus V2 standard main battery is a seri

Page 12 - Continued from previous page

Manual revision 006 Appendix II: Electronics Disassembly/Reassembly SBE 19plus V2 109 Appendix II: Electronics Disassembly/Reassembly Disassem

Page 13

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 11 Specifications Temperature (°C) Conductivity (S/m) Pressure Measurem

Page 14 - Sample Timing (Moored Mode)

Manual revision 006 Appendix III: Command Summary SBE 19plus V2 110 Appendix III: Command Summary CATEGORY COMMAND DESCRIPTION Status GetCD Get an

Page 15 - Battery Endurance

Manual revision 006 Appendix III: Command Summary SBE 19plus V2 111 CATEGORY COMMAND DESCRIPTION Output Format Setup OutputFormat=x x=0: output r

Page 16

Manual revision 006 Appendix III: Command Summary SBE 19plus V2 112 CATEGORY COMMAND DESCRIPTION Data Upload Stop logging before uploading. GetSam

Page 17 - External Power

Manual revision 006 Appendix III: Command Summary SBE 19plus V2 113 CATEGORY COMMAND DESCRIPTION Calibration Coefficients (F=floating point number

Page 18

Manual revision 006 Appendix IV: AF24173 Anti-Foulant Device SBE 19plus V2 114 Appendix IV: AF24173 Anti-Foulant Device AF24173 Anti-Foulant Devic

Page 19 - Magnetic Reed Switch

Manual revision 006 Appendix IV: AF24173 Anti-Foulant Device SBE 19plus V2 115 AF24173 Anti-Foulant Device FOR USE ONLY IN SEA-BIRD ELECTRONICS’ CO

Page 20 - Vertical Mount

Manual revision 006 Appendix IV: AF24173 Anti-Foulant Device SBE 19plus V2 116 PRECAUTIONARY STATEMENTS HAZARD TO HUMANS AND DOMESTIC ANIMALS DANG

Page 21

Manual revision 006 Appendix IV: AF24173 Anti-Foulant Device SBE 19plus V2 117 STORAGE AND DISPOSAL PESTICIDE STORAGE: Store in original containe

Page 22

Manual revision 006 Appendix V: Replacement Parts SBE 19plus V2 118 Appendix V: Replacement Parts Part Number Part Application Description Quantit

Page 23 - Horizontal Mount

Manual revision 006 Appendix V: Replacement Parts SBE 19plus V2 119 continued from previous page Part Number Part Application Description Quantit

Page 24 - Section 3:

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 12 Continued from previous page Internal Batteries (nominal capacity) Sta

Page 25 - See Seaterm232’s Help files

Manual revision 006 Appendix V: Replacement Parts SBE 19plus V2 120 continued from previous page Part Number Part Application Description Quantit

Page 26

Manual revision 006 Appendix VI: Manual Revision History SBE 19plus V2 121 Appendix VI: Manual Revision History Manual Version Date Description 00

Page 27

Manual revision 006 Appendix VI: Manual Revision History SBE 19plus V2 122 006 04/11 • Firmware 2.3: Add compatibility with WET Labs RS-232 senso

Page 28

Manual revision 006 Index SBE 19plus V2 123 Index . .con file · 50, 51, 64, 78, 80, 89, 101 .xmlcon file · 50, 51, 64, 78, 80, 89, 101 A Aanderaa Op

Page 29

Manual revision 006 Index SBE 19plus V2 124 M Magnetic reed switch · 19 Maintenance · 92 Manual revision history · 121 Memory · 11, 19 Modes · See S

Page 30

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 13 Dimensions and End Cap Connectors Dimensions in millimeters (inches)

Page 31 - Profiling Mode

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 14 Sample Timing (Moored Mode) Sample timing in Moored Mode is dependent

Page 32 - Moored Mode

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 15 Batteries For the main battery, the SBE 19plus V2 uses nine D-cell al

Page 33 - Pump Operation - General

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 16 Moored Mode Examples A 19plus V2 with strain-gauge pressure sensor a

Page 34 - Pump Operation - Moored Mode

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 17 External Power The SBE 19plus V2 can be powered from an external sourc

Page 35

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 18 Supplying Enough Power to SBE 19plus V2 Another consideration in de

Page 36 - Real-Time Setup

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 19 Data Storage The SBE 19plus V2 has a 64 Mbyte FLASH memory. Shown bel

Page 37 - Timeout Description

2 Limited Liability Statement Extreme care should be exercised when using or servicing this equipment. It should be used or serviced only by personn

Page 38 - Command Descriptions

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 20 Configuration Options and Plumbing The standard SBE 19plus V2 include

Page 39

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 21 Shown below is the vertical mount plumbing arrangement of a 19plus V2

Page 40 - Status Commands (continued)

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 22 Shown below is the vertical mount plumbing arrangement of a 19plus V2 c

Page 41

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 23 Horizontal Mount Shown below is the horizontal mount plumbing arrangem

Page 42

Manual revision 006 Section 3: Power and Communications Test SBE 19plus V2 24 Section 3: Power and Communications Test This section describes soft

Page 43

Manual revision 006 Section 3: Power and Communications Test SBE 19plus V2 25 Test 1. Double click on SeatermV2.exe. The main screen looks like th

Page 44

Manual revision 006 Section 3: Power and Communications Test SBE 19plus V2 26 Following is a description of the menus: Menu Description Equivalent

Page 45

Manual revision 006 Section 3: Power and Communications Test SBE 19plus V2 27 3. If this is the first time Seaterm232 is being used, the Serial Por

Page 46

Manual revision 006 Section 3: Power and Communications Test SBE 19plus V2 28 Taking a look at the Send Commands window: You can use the Send Com

Page 47

Manual revision 006 Section 3: Power and Communications Test SBE 19plus V2 29 5. Display 19plus V2 status information by typing DS and pressing th

Page 48

Manual revision 006 Table of Contents SBE 19plus V2 3 Table of Contents Section 1: Introduction ...

Page 49

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 30 Section 4: Deploying and Operating SBE 19plus V2 This sectio

Page 50

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 31 Profiling Mode The SBE 19plus V2 samples data at 4 Hz (one sa

Page 51

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 32 Moored Mode At pre-programmed intervals, the SBE 19plus V2 wa

Page 52

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 33 Pump Operation - General Do not run the pump dry. The pump is

Page 53

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 34 Pump Operation - Moored Mode Pump operation is governed by tw

Page 54

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 35 Moored Mode Pump Setting Recommendations Sea-Bird provides th

Page 55

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 36 Real-Time Setup Baud Rate and Cable Length Without a Sea-Bi

Page 56

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 37 With a Sea-Bird Deck Unit Set the 19plus V2 baud rate to 4800

Page 57

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 38 Command Descriptions This section describes commands and prov

Page 58 - Moored Mode (MM)

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 39 Status Commands GetCD Get and display configuration data, wh

Page 59

Manual revision 006 Table of Contents SBE 19plus V2 4 Section 5: Routine Maintenance and Calibration ... 92 Corrosion Precau

Page 60

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 40 Status Commands (continued) Example: 19plus V2 in Profiling

Page 61

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 41 Status Commands (continued) GetSD Get and display status dat

Page 62

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 42 Status Commands (continued) GetCC Get and display calibratio

Page 63

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 43 Status Commands (continued) GetEC Get and display event coun

Page 64

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 44 Status Commands (continued) GetHD Get and display hardware d

Page 65

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 45 Status Commands (continued) DS Get and display operating stat

Page 66 - Data Output Formats

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 46 Status Commands (continued) Moored Mode (MM) • Firmware v

Page 67

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 47 Status Commands (continued) DCal Get and display calibration

Page 68

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 48 General Setup Commands DateTime=mmddyyyyhhmmss Set real-tim

Page 69

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 49 General Setup Commands (continued) InitLogging Initialize lo

Page 70

Manual revision 006 Section 1: Introduction SBE 19plus V2 5 Section 1: Introduction This section includes a Quick Start procedure, and photos of a

Page 71

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 50 Pressure and Voltage Sensor Setup Commands PType=x Pressur

Page 72

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 51 RS-232 Sensor Setup Commands The SBE 19plus V2 can interface

Page 73

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 52 RS-232 Sensor Setup Commands (continued) Setup for WET Labs S

Page 74

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 53 RS-232 Sensor Setup Commands (continued) Setup for GTD: SBE

Page 75

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 54 RS-232 Sensor Setup Commands (continued) Setup for Aanderaa

Page 76

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 55 Output Format Setup Commands See Data Output Formats after t

Page 77

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 56 Profiling Mode Setup Commands Profiling mode setup commands

Page 78 - Setup for Deployment

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 57 Moored Mode Setup Commands Moored mode setup commands follow

Page 79 - Deployment

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 58 Logging Commands Logging commands direct the SBE 19plus V2 t

Page 80

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 59 Logging Commands (continued) StartNow Start logging now.

Page 81

Manual revision 006 Section 1: Introduction SBE 19plus V2 6 Unpacking SBE 19plus V2 Shown below is a typical SBE 19plus V2 shipment.

Page 82 - Acquiring Real-Time Data

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 60 Data Upload Commands Stop logging before uploading data. If m

Page 83

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 61 Polled Sampling Commands These commands request a single samp

Page 84 - Recovery

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 62 Testing Commands The 19plus V2 takes and outputs 100 samples

Page 85 - Uploading Data

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 63 Testing Commands continued TWetLabs Measure WET Labs RS-232

Page 86

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 64 Calibration Coefficients Commands Calibration coefficients ar

Page 87 - Command/Data Echo Area

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 65 Hardware Configuration Commands The following commands are us

Page 88

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 66 Data Output Formats The SBE 19plus V2 stores data in a compac

Page 89

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 67 OutputFormat=0 (raw frequencies and voltages in Hex) Data is

Page 90

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 68 OutputFormat=1 (engineering units in Hex) Data is output in t

Page 91 - Editing Raw Data File

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 69 OutputFormat=2 (raw frequencies and voltages in decimal) Data

Page 92 - Corrosion Precautions

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 7 Section 2: Description of SBE 19plus V2 This section describes the func

Page 93 - Plumbing Maintenance

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 70 OutputFormat=3 (engineering units in decimal) Data is output

Page 94 - Replacing Alkaline Batteries

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 71 OutputFormat=4 (pressure and scan number in Hex) Data is outp

Page 95

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 72 Uploaded Data (from GetSamples:b,e or DDb,e): <?xml?> &l

Page 96

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 73 Polled Data from SL, SLT, TS, TSS, or TSSOn: If OutputUCSD=Y a

Page 97 - Do not recharge the Ni-Cad

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 74 Optimizing Data Quality for Profiling Applications Our deploy

Page 98 - Barbed caps for cleaning

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 75 When very heavy seas cause severe ship motion, the 19plus V2 d

Page 99 - Pump Maintenance

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 76 Installing Anti-Foul Fittings for Moored Applications The SBE

Page 100 - 8-inch socket wrench;

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 77 4. Intake – A. Remove the two hex head screws attaching the

Page 101 - Sensor Calibration

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 78 Setup for Deployment 1. Install new batteries or ensure the

Page 102 - Pressure Sensor

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 79 Deployment 1. Install a cable or dummy plug for each connec

Page 103 - Section 6: Troubleshooting

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 8 SBE 19plus V2 options / accessories include: • Titanium housing for use

Page 104 - Problem 4: Program Corrupted

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 80 Acquiring Real-Time Data with Seasave Verifying Contents of C

Page 105 - Glossary

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 81 3. The configuration information appears on the Instrument C

Page 106

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 82 Acquiring Real-Time Data Instructions below are for an SBE 19

Page 107 - Sensors

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 83 5. In the Start Real-Time Data Acquisition dialog box, click

Page 108 - Battery Wiring

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 84 Recovery Physical Handling 1. Rinse the instrument and cond

Page 109 - Appendix II:

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 85 Uploading Data 1. Double click on SeatermV2.exe. The main sc

Page 110 - WetLabs=x

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 86 6. Click Upload to upload stored data. Seaterm232 responds as

Page 111

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 87 7. Click the Header Form tab to customize the header: The ent

Page 112

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 88 9. Ensure all data has been uploaded by reviewing and proces

Page 113

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 89 Processing Data Using SBE Data Processing 1. Convert the .he

Page 114 - AF24173 ANTI-FOULANT DEVICE

Manual revision 006 Section 2: Description of SBE 19plus V2 SBE 19plus V2 9 • SBE 36 CTD Deck Unit and Power Data Interface Module (PDIM) - These i

Page 115 - AF24173 Anti-Foulant Device

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 90 3. In the Open dialog box, select the .xmlcon or .con file an

Page 116

Manual revision 006 Section 4: Deploying and Operating SBE 19plus V2 SBE 19plus V2 91 Editing Raw Data File Sometimes users want to edit the raw .h

Page 117

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 92 Section 5: Routine Maintenance and Calibration This section re

Page 118

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 93 Plumbing Maintenance For an SBE 19plus V2 with plumbing config

Page 119

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 94 Replacing / Recharging Batteries Leave the batteries in place w

Page 120

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 95 Recharging Optional Nickel Metal Hydride Batteries See the NiMH

Page 121

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 96 4. Reinstall the battery pack in the housing: A. Align the bat

Page 122

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 97 Recharging Optional Nickel-Cadmium Batteries The Ni-Cad battery

Page 123

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 98 Conductivity Cell Maintenance The SBE 19plus V2’s conductivity

Page 124

Manual revision 006 Section 5: Routine Maintenance and Calibration SBE 19plus V2 99 Pressure Sensor Maintenance Pressure sensor maintenance varies,

Commentaires sur ces manuels